Rezoning Planned Development Zones

A view down the street in a residential neighborhood

The City of Madison is exploring the rezoning of several single- and two-family Planned Development Zones (PDs) into conventional zoning districts.

Planned Development zoning is site-specific zoning, where specific use and development requirements are written for each individual PD zone. Conventional zoning districts are districts whose rules are wholly within the City’s zoning code. Conventional zoning districts may be mapped and used in various areas throughout the city. 


Public Information Meetings

The City of Madison is hosting two virtual Public Information Meetings on its Planned Development Rezoning project. Residents interested in attending one of the meetings will need to register ahead of time to receive a link to the virtual meeting. Meetings will be held on:

June 22, 2026, at 6:00pm Central Time

Watch Meeting Recording

Download Presentation Slides

June 25, 2026, at 6:00pm Central Time

Register to Receive Meeting Link


Project Background

Currently, minor changes to a property that should be a straightforward process to navigate—like adding an egress window or a patio space—can quickly become complicated if a home is located within a PD.  

City staff believes rezoning PDs into conventional zoning districts will lead to more equity among property owners across Madison by:

  • Making sure everyone has the same opportunity to make changes to their property
  • Making zoning rules clearer, more objective, and easily accessible
  • Creating consistent standards for the same types of development
  • Making the building permit approval process standardized, fair, and faster for similar single- and two-family properties throughout the city
  • Allowing neighborhoods to evolve to fit residents’ needs over time
  • Allowing more properties to take advantage of recent zoning changes, like allowing two-unit homes or Accessory Dwelling Units in more areas

Proposed New Zoning Districts

This list of proposed PD rezonings is being provided to let property owners in PD zones know which conventional zoning district is being proposed for their property.

Search by Alder District

Download the Full List

These single- or two-family properties in PDs are being proposed to be rezoned into one of seven conventional zoning districts:

  • Suburban Residential – Consistent 1 (SR-C1)
  • Suburban Residential – Consistent 2 (SR-C2)
  • Suburban Residential – Consistent 3 (SR-C3)
  • Traditional Residential – Consistent 1 (TR-C1)
  • Traditional Residential – Consistent 2 (TR-C2)
  • Traditional Residential – Consistent 3 (TR-C3)
  • Traditional Residential – Consistent 4 (TR-C4)

SR-C1 Setback Requirements

All measurements are in feet unless otherwise noted:

Category Single-family detached Two-family Two unit Two-family - Twin Nonresidential 
Minimum Lot Area (sq. ft.) 6,000 6,000 3,000 per dwelling unit 8,000 
Minimum Lot Width 55 55 27 per dwelling unit 60 
Minimum Front Yard Setback 30 30 30 30 
Minimum Side Yard Setback 
Minimum Reversed Corner Side Yard Setback 15 15 15 30 
Minimum Rear Yard Setback Lesser of 30% lot depth or 30, see (1.) below; Alley accessed: 3, 
See (2.) below 
Lesser of 30% lot depth or 30, see (1.) below; Alley accessed: 3, 
See (2.) below 
Lesser of 30% lot depth or 30, see (1.) below; Alley accessed: 3, 
See (2.) below 
Lesser of 30% lot depth or 35, see (1.) below 
Maximum height 2 stories/35 2 stories/35 2 stories/35 35 
Maximum lot coverage 50% 50% 50% 60% 
Maximum building coverage n/a n/a n/a 50% 
  1. If the existing principal structure and any additions to it covers twenty percent (20%) or less of the lot area, the rear yard setback may be reduced by twenty-five percent (25%). 
  2. Only a one-story, alley-accessed attached garage projection for garage purposes may have a minimum rear yard setback of three (3) feet. 

Other requirements can be found in Chapter 28.035 of the zoning code

SR-C2 Setback Requirements

All measurements are in feet unless otherwise noted:

Category Single-family detached Two-family Two unit Two-family - Twin Nonresidential 
Minimum Lot Area (sq. ft.) 5,000 5,000 2,500 per dwelling unit 6,000 
Minimum Lot Width 50 50 25 per dwelling unit 50 
Minimum Front Yard Setback 30 30 30 30 
Minimum Side Yard Setback 
Minimum Reversed Corner Side Yard Setback 15 15 15 30 
Minimum Rear Yard Setback Lesser of 30% lot depth or 30, see (1.) below; Alley accessed: 3, 
See (2.) below 

Lesser of 30% lot depth or 30, see (1.) below; Alley accessed: 3, 
See (2.) below 

 

Lesser of 30% lot depth or 30, see (1.) below; Alley accessed: 3, 
See (2.) below 

 

Lesser of 30% lot depth or 35, see (1.) below 
Maximum height 2 stories/35 2 stories/35 2 stories/35 35 
Maximum lot coverage 50% 50% 50% 35 
Maximum building coverage n/a n/a n/a n/a 
  1. If the existing principal structure and any additions to it covers twenty percent (20%) or less of the lot area, the rear yard setback may be reduced by twenty-five percent (25%). 
  2. Only a one-story, alley-accessed attached garage projection for garage purposes may have a minimum rear yard setback of three (3) feet. 

Other requirements can be found in Chapter 28.036 of the zoning code

SR-C3 Setback Requirements

All measurements are in feet unless otherwise noted:

Category Single-family detached Two-family Two unit Two-family - Twin Nonresidential 
Minimum Lot Area (sq. ft.) 5,000 5,000 2,500 per dwelling unit 6,000 
Minimum Lot Width 50 50 25 per dwelling unit 50 
Minimum Front Yard Setback 25 25 25 25 
Minimum Side Yard Setback 
Minimum Reversed Corner Side Yard Setback 15 15 15 25 
Minimum Rear Yard Setback Lesser of 30% lot depth or 30, see (1.) below; Alley accessed: 3, see (2.) below 

Lesser of 30% lot depth or 30, see (1.) below; Alley accessed: 3, see (2.) below 

 

Lesser of 30% lot depth or 30, see (1.) below; Alley accessed: 3, see (2.) below 

 

Equal to building height but at least 35, see (1.) below 
Maximum height 2 stories/35 2 stories/35 2 stories/35 35 
Maximum lot coverage 60% 60% 60% 60% 
Maximum building coverage n/a n/a n/a 50% 
  1. If the existing principal structure and any additions to it covers twenty percent (20%) or less of the lot area, the rear yard setback may be reduced by twenty-five percent (25%).  
  2. Only a one-story, alley-accessed attached garage projection for garage purposes may have a minimum rear yard setback of three (3) feet. 

Other requirements can be found in Chapter 28.037 of the zoning code

TR-C1 Setback Requirements

All measurements are in feet unless otherwise noted:

Category Single-family detached Two-family Two unit Two-family - Twin Nonresidential 
Minimum Lot Area (sq. ft.) 5,000 5,000 2,500 per dwelling unit 6,000 
Minimum Lot Width 45 45 22 per dwelling unit 50 
Minimum Front Yard Setback 20 20 20 20 
Maximum Front Yard Setback 30 ft. or up to 20% greater than block average 30 ft. or up to 20% greater than block average 30 ft. or up to 20% greater than block average n/a 
Minimum Side Yard Setback 10 
Minimum Reversed Corner Side Yard Setback 15 15 15 15 
Minimum Rear Yard Setback Lesser of 30% lot depth or 30, see (1.) below; Alley accessed: 3, see (2.) below 

Lesser of 30% lot depth or 30, see (1.) below; Alley accessed: 3, see (2.) below 

 

Lesser of 30% lot depth or 30, see (1.) below; Alley accessed: 3, see (2.) below Equal to building height but at least 35. see (1.) below 
Maximum height 2 stories/35 2 stories/35 2 stories/35 35 
Maximum lot coverage 50% 50% 50% 65% 
Maximum building coverage n/a n/a n/a 50% 
  1. If the existing principal structure and any additions to it covers twenty percent (20%) or less of the lot area, the rear yard setback may be reduced by twenty-five percent (25%). 
  2. Only a one-story, alley-accessed attached garage projection for garage purposes may have a minimum rear yard setback of three (3) feet. 

Other requirements can be found in Chapter 28.042 of the zoning code

TR-C2 Setback Requirements

All measurements are in feet unless otherwise noted:

Category Single-family detached Two-family Two unit Two-family - Twin Nonresidential 
Minimum Lot Area (sq. ft.) 4,000 4,000 2,000 per dwelling unit 4,800 
Minimum Lot Width 40 40 20 per dwelling unit 40 
Minimum Front Yard Setback 20 20 20 20 
Maximum Front Yard Setback 30 ft. or up to 20% greater than block average 30 ft. or up to 20% greater than block average 30 ft. or up to 20% greater than block average n/a 
Minimum Side Yard Setback 5; 
If lot width < 50: 10% lot width 
5; 
If lot width < 50: 10% lot width 
5; 
If lot width < 50: 10% lot width 
10 
Minimum Reversed Corner Side Yard Setback 12 12 12 20 
Minimum Rear Yard Lesser of 30% lot depth or 30; 
Alley accessed: 3, see (1.) below 
Lesser of 30% lot depth or 30; 
Alley accessed: 3, see (1.) below 
Lesser of 30% lot depth or 30; 
Alley accessed: 3, see (1.) below 
Equal to building height but at least 30 
Maximum height 2 stories/35 2 stories/35 2 stories/35 35 
Maximum lot coverage 65% 65% 65% 65% 
Maximum building coverage n/a n/a n/a 50% 
  1. Only a one-story, alley-accessed attached garage projection for garage purposes may have a minimum rear yard setback of three (3) feet. 

Other requirements can be found in Chapter 28.043 of the zoning code

TR-C3 Setback Requirements

All measurements are in feet unless otherwise noted:

Category Single-family detached Two-family Two unit Two-family - Twin Nonresidential 
Minimum Lot Area (sq. ft.) 3,000 3,000 1,500 per dwelling unit 4,000 
Minimum Lot Width 30 30 15 per dwelling unit 40 
Minimum Front Yard Setback 15 15 15 15 
Maximum Front Yard Setback 30 ft. or up to 20% greater than block average 30 ft. or up to 20% greater than block average 30 ft. or up to 20% greater than block average n/a 
Minimum Side Yard Setback 
Lot width < 50: 10% lot width 

Lot width < 50: 10% lot width 

Lot width < 50: 10% lot width 
Minimum Reversed Corner Side Yard Setback 8 (10 for garage) 8 (10 for garage) 8 (10 for garage) 15 
Minimum Rear Yard Lesser of 20% lot depth or 20; 
Alley-accessed: 3, see (1.) below 
Lesser of 20% lot depth or 20; 
Alley-accessed: 3, see (1.) below 
Lesser of 20% lot depth or 20; 
Alley-accessed: 3, see (1.) below 
Equal to building height but at least 20 
Maximum height 2 stories/35 2 stories/35 2 stories/35 35 
Maximum lot coverage 75% 75% 75% 75% 
Maximum building coverage n/a n/a n/a 65% 
  1. Only a one-story, alley-accessed attached garage projection for garage purposes may have a minimum rear yard setback of three (3) feet. 

Other requirements can be found in Chapter 28.044 of the zoning code

TR-C4 Setback Requirements

All measurements are in feet unless otherwise noted:

Category Single-family detached Two-family Two unit Two-family Twin Three-unit Nonresidential 
Minimum Lot Area (sq. ft.) 4,000 4,000 2,000 per dwelling unit 4,000 4,800 
Minimum Lot Width 40 40 20 per dwelling unit 40 40 
Minimum Front Yard Setback 20 20 20 20 20 
Maximum Front Yard Setback 30 ft. or up to 20% greater than block average 30 ft. or up to 20% greater than block average 30 ft. or up to 20% greater than block average 30 ft. or up to 20% greater than block average n/a 
Minimum Side Yard Setback 
Lot width <50: 10% lot width 

Lot width <50: 10% lot width 

Lot width <50: 10% lot width 

Lot width <50: 10% lot width 
Minimum Reversed Corner Side Yard Setback 12 12 12 12 20 
Minimum Rear Yard Lesser of 30% lot depth or 30; Alley accessed: 3, see (1.) below Lesser of 30% lot depth or 30; Alley accessed: 3, see (1.) below Lesser of 30% lot depth or 30; Alley accessed: 3, see (1.) below Lesser of 30% lot depth or 30; Alley accessed: 3, see (1.) below Equal to building height but at least 30 
Maximum height 2 stories/35 2 stories/35 2 stories/35 2 stories/35 35 
Maximum lot coverage 65% 65% 65% 65% 65% 
Maximum building coverage n/a n/a n/a n/a 50% 
  1. Only a one-story, alley-accessed attached garage projection for garage purposes may have a minimum rear yard setback of three (3) feet. 

Other requirements can be found in Chapter 28.045 of the zoning code


Frequently Asked Questions

How do PDs work?

Each PD is unique, with rules for things like setbacks, building height, lot coverage, design, and the design review process.  

The Common Council approves each PD and any specific amendments to the PD, with recommendations from the Plan Commission and Urban Design Commission.

Why do we have PDs?

Planned Development Zoning became popular in the 1980s due to alders, neighborhood stakeholders, and developers wanting a greater level of land use control, particularly in newer neighborhoods. Most of the value of a PD was upfront, in that it allowed entire neighborhoods to be designed at once. 

What are some of the challenges with PDs?

PDs have highly-specific zoning text that was established when the PD was first created. This text is extremely difficult to change, meaning properties within that PD are locked into restrictions that were thought to be best practice at that time. Since these areas have their own zoning rules, they do not get the benefit of recent zoning code changes made by the City. While the City's zoning code may evolve over time to better reflect the needs of the City and its residents, a PD zoning text is more rigid. This makes it incredibly difficult for properties to make even incremental changes over time. 

Also, because there are so many PDs across Madison, it is not feasible for the City to make the zoning rules for these individual PDs easily accessible online, like it is for conventional zoning districts. If a property owner living in a PD has a question about what is allowed on their property, it can take a significant amount of time for City Zoning staff to find the appropriate PD zoning document, read through its requirements, and provide an answer. 

Some PDs require even the smallest property changes to go through architectural review boards comprised of developers or other property owners and get approval from that body before the City can issue a building permit for the project. The City does not have any control over these unelected bodies, and they can prevent City staff from approving something that would otherwise be allowed by the PD's zoning text or the Citywide zoning code. 

City staff typically does not know who serves on these architectural review boards or have contact information for those members and can only tell a homeowner looking to build a deck or add an egress basement window in these PDs to try to track down those approvals before applying for a building permit. 

How is the building permit process different in PDs?

Applying for a building permit within a PD involves several steps and processes, including: 

  • Staff locating and reviewing PD files 
  • Determining whether the proposed changes are allowed within the PD 
    • If not, a Major Alteration to the PD will need to be submitted 
  • Determining whether the PD established Zoning Standards for review or if the PD allows projects to move forward without a Minor Alteration 
    • If not, the property owner needs to submit  Minor Alteration to the PD, which includes: 
      • Paying a $100 review fee 
      • Getting a recommendation from their district alder 
      • Filling out a recording form for the Dane County Register of Deeds 
      • Paying a $30 filing fee for the Dane County Register of Deeds 
      • Waiting 2-3 weeks for the submission to be reviewed 
  • Determining whether the PD requires approval from an Architectural Review Committee, then the property owner getting that approval 
  • Additional review from Zoning staff after Architectural Review Committee approval 
  • If a Minor Alteration needs to be submitted, that alteration needs to be approved by the City of Madison's Planning Director 

The process for conventional zoning districts is much simpler, with staff reviewing the site plan based on the zoning requirements for the zoning district, as outlined in MGO Chapter 28. If the site plan meets all requirements, it is approved by Zoning staff and the building permit is issued without any additional steps.

Flow chart showing the difference in the processes between getting a building permit in a traditional zoning district vs. PDs

Download Review Process Flowchart

How can I tell if my property is in a PD?

You can enter your address into the City of Madison Zoning District Map or the City Assessor's Property Look-Up tool to find if your zoning district is PD. 

What other restrictions may be on my property?

Beyond PDs, some properties may be subject to regulations from a homeowners' association or a private restrictive covenant. The City is not a party to these agreements, meaning it does not decide what is included in them and does not enforce them. If your property has valid covenants, you will most likely need to work with your homeowners' association or a similar group to work out what they enforce or review. 

Legally, private covenants “run with the land," meaning they apply to the property itself and not the specific owner who originally made the agreement. You can usually find out if your property is under a covenant by finding the covenant in your title search documents or by doing research at the Register of Deeds.

It is the property owner's responsibility to determine if private covenants apply before starting a project on their property, regardless of what zoning district their property is in.

Why rezone my property to a conventional zoning district if my property will still have private covenants?

Not all covenants are the same, and not all homeowners associations enforce them to the same degree. Rezoning is the tool the City can use to help people have the most flexibility, since we are not a party to the private covenants. 

Will assessments or fees for my Homeowners Association (HOA) be affected?

No, assessments and fees are not tied to a property's zoning district. Homeowners associations will still be able to collect fees like any other non-Planned Development (PD) zoned property and use them to fund operations, maintenance of common amenities and property, etc.

Was this page helpful to you? * required